EVS XT-3 Uživatelský manuál Strana 68

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 94
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 67
10.05.D
XT33 Series DISK RECORDERVersion 10.05 - Software Technical Reference
EVS Broadcast Equipment SA July 2011
60
Important:
By default, the online rebuild process takes up 10% of the disk
bandwidth. If you want to change this, contact EVS support.
RETRIEVING LOGS
If you suspect that the drive disconnection in operation was not due to a severe
disk failure, but perhaps to the server being too prompt to disconnect a drive, you
must run a hardware check immediately after ending the session during which the
disk was disconnected.
Don’t rebuild the RAID, but press simultaneously the ALT+L keys to generate the
log file C:\LSMCE\DATA\LOG\SCSI.LOG, and send this file to EVS for detailed
analysis. Note that this procedure is only valid if the drive is disconnected during
operation, not for a drive being disconnected when booting the system.