EVS XT2+ Uživatelský manuál Strana 75

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 85
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 74
XT2 Series DISK RECORDER - Version 10.05 - Software Technical Reference Manual
Issue
10.05.A
EVS Broadcast Equipment SA July 2011
67
3.2.6 LOG MANAGEMENT
The 5
th
page of the Server Monitoring section displays a menu dedicated to log
management. This new page allows a user-friendly and easy management of the
logs where log files can be accessed from a remote computer while the Multicam
is still in use.
Log File Types
The left column displays items related to microcode. The right column displays
those of the Multicam.
Each item has two associated log files:
a regular log file
a log file logging only errors
Criticality Levels
Each item has a criticality level that can be modified:
The lowest and default level of criticality is ‘Critical’, where the log is limited
to recording critical and important commands.
An intermediate level is ‘Normal’
The highest level is ‘Debug’ which basically records every command.
This highest level should never be chosen without advice of qualified EVS
staff.
The default value for all items is “Critical”.
A help screen can be reached by pressing SHIFT+F1.